<?xml version="1.0" encoding="UTF-8"?>
<article article-type="research-article" dtd-version="1.3" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group>
        <journal-title>Czech and Slovak Ophthalmology</journal-title>
      </journal-title-group>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="publisher-id">310</article-id>
      <article-id pub-id-type="doi">10.31348/2024/6</article-id>
      <article-categories>
        <subj-group>
          <subject>Original article</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title>Diagnostic Importance of Oct Pachymetry in Keratoconus</article-title>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author">
          <name>
            <surname>Benca Kapitánová</surname>
            <given-names>Karolína</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-9209-0223</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Javorka</surname>
            <given-names>Michal</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-7562-5193</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Vida</surname>
            <given-names>Rastislav</given-names>
          </name>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Halička</surname>
            <given-names>Juraj</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-0234-3616</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Králik</surname>
            <given-names>Michal</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-8566-7637</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Prídavková</surname>
            <given-names>Zuzana</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-2610-6711</contrib-id>
        </contrib>
        <contrib contrib-type="author">
          <name>
            <surname>Žiak</surname>
            <given-names>Peter</given-names>
          </name>
          <contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-3910-6174</contrib-id>
        </contrib>
      </contrib-group>
      <pub-date date-type="pub" publication-format="electronic">
        <day>1</day>
        <month>2</month>
        <year>2024</year>
      </pub-date>
      <issue>1</issue>
      <elocation-id>4</elocation-id>
      <abstract>
        <p>Purpose: To evaluate the value of AS OCT pachymetry as a method capable of detecting early differences between keratoconus, latent keratoconus and corneal astigmatism based on measurements of the parameters of corneal epithelial thickness and total corneal thickness. Methods: This study analyzed 162 eyes of 89 patients examined with a Zeiss Cirrus 500 Anterior Segment Premier Module. OCT Pachymetry maps were created in 97 eyes with keratoconus, 33 eyes with latent (forme fruste) keratoconus, and 32 eyes with regular corneal astigmatism (≥ 1.5 Dcyl). The parameters of epithelial thickness (central epithelial thickness in the 2 mm zone, paracentral epithelial thickness in the 2–5mm zone, minimal and maximal epithelial thickness) and total corneal thickness (S-I in the 2–5 mm zone, SN-IT in the 2–5 mm zone, minimal thickness, max-min thickness) were analyzed in all pachymetry maps. Results: Statistically significant differences were determined in 3 parameters of epithelial thickness (paracentral epithelial thickness in the 2–5 mm zone, minimal epithelial thickness, maximal epithelial thickness) between group A and group B (p &lt; 0.001), as well as between group A and group C (p &lt; 0.001). Statistically significant differences were determined in 3 parameters of total corneal thickness (S-I in the 2–5 mm zone, SN-IT in the 2–5 mm zone, minimal thickness) between group A and group B (p &lt; 0.001), between group A and group C (p &lt; 0.001), as well as between group B and group C (p &lt; 0.001). Conclusion: AS OCT Pachymetry maps are a reliable method capable of detecting differences between keratoconus and corneal astigmatism based on the comparison of paracentral epithelial thickness in the 2–5 mm zone, minimum epithelial thickness, and maximum epithelial thickness. Furthermore, based on the evaluation of the parameters of total corneal thickness, it is a method capable of defining the differences between keratoconus, latent keratoconus and corneal astigmatism (S-I in the 2–5 mm zone, SN-IT in the 2–5 mm zone and minimum thickness). In the statistical analysis, the most reliable parameters appear to be: the difference between groups A, B and C in the parameters S-I in the 2–5 mm paracentral zone, SN-IT in the 2–5 mm paracentral zone and in the values of minimum corneal thickness.</p>
      </abstract>
      <kwd-group>
        <kwd>anterior segment OCT</kwd>
        <kwd>keratoconus</kwd>
        <kwd>OCT pachymetry</kwd>
      </kwd-group>
    </article-meta>
  </front>
  <back>
    <ref-list>
      <title>References</title>
      <ref id="R1720">
        <mixed-citation>Vazirani J, Basu S. Keratoconus: current perspectives. Clin ophthalmol. 2013;7:2019-2030.</mixed-citation>
      </ref>
      <ref id="R1721">
        <mixed-citation>Studeny P. a kol. Keratokonus. Praha: Maxdorf. 2020. ISBN 978-80- 7345-665-8.</mixed-citation>
      </ref>
      <ref id="R1722">
        <mixed-citation>Li Y, Tan O, Brass R, Weiss JL, Huang D. Corneal epithelial thickness mapping by fourier-domain optical coherence tomography in normal and keratoconic eyes. Ophthalmology. 2012;119:2425-2433.</mixed-citation>
      </ref>
      <ref id="R1723">
        <mixed-citation>Gokul A, Vellara HR, Patel DV. Advanced anterior segment imaging in keratoconus: a review: Imaging the keratoconic cornea. Clin Exp Ophthalmol. 2018;46:122-132.</mixed-citation>
      </ref>
      <ref id="R1724">
        <mixed-citation>Kanellopoulos AJ, Asimellis G. Anterior segment optical coherence tomography: assisted topographic corneal epithelial thickness distribution imaging of a keratoconus patient. Case Rep Ophthalmol. 2013;18:74-78.</mixed-citation>
      </ref>
      <ref id="R1725">
        <mixed-citation>Lohmann CP, Resichl U, Marshall J. Regression and epithelial hyperplasia after myopic photorefractive keratectomy in a human cornea. J Cataract Refract Surg. 1999;25:712-715.</mixed-citation>
      </ref>
      <ref id="R1726">
        <mixed-citation>Reinstein DZ, Srivannaboon S, Gobbe M, et al. Epithelial thickness profile changes induced by myopic LASIK as measured by Artemis very high-frequency digital ultrasound. J Refract Surg. 2009;25:444-450.</mixed-citation>
      </ref>
      <ref id="R1727">
        <mixed-citation>Franco J, White CA, Kruh JN. Analysis of compensatory corneal epithelial thickness changes in keratoconus using corneal tomography. Cornea. 2019;39:298-302.</mixed-citation>
      </ref>
      <ref id="R1728">
        <mixed-citation>Ramos JLB, Li Y, Huang D. Clinical and research applications of anterior segment optical coherence tomography – a review. Clin Exp Ophthalmol. 2009;37:81-89.</mixed-citation>
      </ref>
      <ref id="R1729">
        <mixed-citation>Ellenhawi FM, Alzankalony YA, Abdellatif MK, Ibrahim AMT. Role of anterior segment optical coherence tomography in the diagnosis of subclinical keratoconus in comparison with the Pentacam. Egypt J Hosp Med. 2018;72:3712-3715.</mixed-citation>
      </ref>
      <ref id="R1730">
        <mixed-citation>Ostadian F, Farrahi F, Mahdian RA. Comparison of corneal epithelial thickness map measured by spectral domain optical coherence tomography in healthy, subclinical and early keratoconus subjects. Med Hypothesis Discov Innov Ophthalmol. 2019;8:85-91.</mixed-citation>
      </ref>
      <ref id="R1731">
        <mixed-citation>Qin B, Chen S, Brass R, et al. Keratoconus diagnosis with an optical coherence tomography-based pachymetric scoring system. J Cataract Refract Surg. 2013;9:1864-1871.</mixed-citation>
      </ref>
      <ref id="R1732">
        <mixed-citation>Sella R, Zangwill LM, Weinreb RN Afshari NA. Repeatability and reproducibility of corneal epithelial thickness mapping with spectral-domain optical coherence tomography in normal and diseased cornea eyes. Am J Ophthalmol. 2019;197:88-97.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
